3.6.2.1.
5-wire Serial Interface Hardware Design
Signal: CT103/TXD*, CT104/RXD*, ~CT105/RTS*, ~CT106/CTS*
The signal ~CT108/DTR* must be managed following the V24 protocol signaling if we want to
use idle mode.
For detailed configuration, please refer to Figure 10 Example of V24/CMOS Serial Link
Implementation for 5-wire UART.
3.6.2.2.
4-wire Serial Interface Hardware Design
Signal: CT103/TXD*, CT104/RXD*, ~CT105/RTS*, ~CT106/CTS*
The signal ~CT108/DTR* can be looped back to ~CT107/DSR from both the AirPrime
WISMO218 side and from the DTE side.
For detailed configuration, please refer to Figure 9 Example of V24/CMOS Serial Link
Implementation for 4-wire UART.
3.6.2.3.
2-wire Serial Interface Hardware Design
This case is possible for a connected external chip, but it is not recommended.
The flow control mechanism has to be managed from the customer side.
Signal: CT103/TXD*, CT104/RXD*
The signal ~CT108/DTR* can be looped back to ~CT107/DSR from both the AirPrime
WISMO218 side and from the DTE side.
The signals ~CT105/RTS*, ~CT106/CTS* are not used, please configure using the AT
command, AT + IFC = 0,0 (see document [2] AirPrime WISMO218 AT Commands Manual).
The signal ~CT105/RTS* can be looped back to ~CT106/CTS* from both the AirPrime
WISMO218 side and from the DTE side.
For detailed configuration, please refer to Figure 8 Example of V24/CMOS Serial Link
Implementation for 2-wire UART.
Note:
The loop back connection of ~CT108/DTR* to ~CT107/DSR is not allowed when the case
AT+PSSLEEP=0 is used, for which sleep mode entry is ~CT108/DTR* level dependent. (Refer to
Note 1 of the Power Consumption section. In order to go to sleep mode properly under such
configuration, AT+PSSLEEP=1 should be used instead. For details, please refer to document [2]
AirPrime WISMO218 AT Commands Manual.
*
According to PC (DTE) view
3.6.3.
Application
The level shifter must be a V28 electrical signal compliant with 2.8V.