Interfaces
Figure 7. Example of RS-232 Level Shifter Implementation for UART
Note that the U1 chip also protects the AirPrime WISMO218 against ESD (Air Discharge) at 15KV.
Table 8:
Recommended Components
Component
Description/Details
Manufacturer
R1, R2
15K
C1, C2, C3, C4, C5
1µF
C6
100nF
C7
6.8uF TANTAL 10V CP32136
AVX
U1
ADM3307EACP
ANALOG DEVICES
J1
SUB-D9 female
R1 and R2 are necessary only during Reset state to force the ~CT125/RI and ~CT109/DCD signals to
HIGH level.
The ADM3307EACP can be powered by the VCC_2V8 (pin 46) of the AirPrime WISMO218 or by an
external regulator at 2.8V.
If the UART interface is connected directly to a host processor, it is not necessary to use level