Instructions for the installer

43

The connection terminals are
located

at

the

rear

of

the

appliance.

For

electrical

connections

see

following

diagram. To access, remove
the rear cover.

For operation on 400-415V3N

∼∼∼∼

: use

an H05RR-F-type five-core cable (5 x
1.5 mm

2

).

For operation on 400-415V2N

∼∼∼∼

: use

an H05RR-F-type four-core cable (4 x
2.5 mm

2

).

For operation on 230-240V

∼∼∼∼

: use an

H05RR-F-type three-core cable (3 x 4
mm

2

).

The cable end to be connected to the
appliance must be provided with an
ground wire (yellow-green) at least 20
mm longer.