Sony HDW-M2000 User Manual
Page 109

Chapter 9
Setup Menus
Chapter 9 Setup Menus
9-13
Menu items in the range 100 to 199, relating to the control panels (Continued)
Menu items in the range 200 to 299, relating to the remote control interface
Select how to use the REMOTE 1-IN(9P) and REMOTE 1-OUT(9P) connectors
on the connector panel.
I&O : Both the IN and OUT connectors are effective whether in local or remote
mode.
IN: Only the IN connector is effective whether in local or remote mode.
OUT: Only the OUT connector is effective whether in local or remote mode.
PANEL: Allows you to select i&o, in, or out using the function menu.
Note
When selecting “panel”, first define user-defined function key RMT1 in the
HOME2 page.
On how to define user-defined function keys in the HOME2 page, refer to the
Maintenance Manual Volume 1.
201
Item number
Item name
Settings
PARA RUN
202
CF FLAG (valid only in
50 Hz mode)
Select the mode for locking to the color framing sent from the remote controller.
8F : Eight-field locking mode
4F/8F: Four- or eight-field locking mode
211
REMOTE 1-PORT
Select whether or not to use synchronized operation for two or more VTRs.
DIS : No synchronized operation
ENA: Use synchronized operation
Note
To use synchronized operation for two or more VTRs, set item 201 to “ENA” on
all of the VTRs.
212
V REMOTE (IMAGE
ENHANCER) CONTROL
SELECT
Select whether to control the up-converter or down-converter when controlling the
image enhancer from the VIDEO CONTROL (15P) connector.
DOWN : Control the down-converter.
UP: Control the up-converter.
U & D: Control both the up-converter and down-converter.
135
TELE-FILE THREAD
COUNTER CLEAR MODE
Select whether to clear the thread counter when formatting a Tele-File.
NOT CLEAR : Do not clear the thread counter.
WHEN FORMAT: Clear the thread counter.
136
TELE-FILE IN OUT INPUT
CONTINUE
Select whether to continuously input log (IN and OUT point) data in the Tele-File
menu screen.
OFF : Do not continuously input log (IN and OUT point) data.
ON: Continuously input log (IN and OUT point) data.
Item number
Item name
Settings