beautypg.com

Palermo and bahia domestic (60 hz), Wiring diagram palermo and bahia domestic (60 hz), Page 30 – Sundance Spas Maxxus User Manual

Page 33

background image

Page 30

OZONA

T

O

R

O

3

GRN

TB1

240 V

AC, 1 PHASE, 60 Hz

USE COPPER CONDUCT

ORS ONL

Y

WIRE SIZE MUST BE

APPROPRIA

TE

PER NEC

AND/OR LOCAL

CODES

RED

RED

BLK

WHT

WHT

RED

BLK

BLK

WHT

BLK

RED

RED

BLK

BLK

BLK

2

1

HEA

TER

5.5 kW

PRESSURE SWITCH

HI - LIMIT

/ FREEZE SENSOR

TEMPERA

TURE SENSOR

J1

J2

J3

F1

30A, 250V

SC-30

PUMP

1

PUMP

2

HOT

TUB

LIGHT

TRANSFORMER

240 V

A

C

Palermo / Bahia Panel

J4

R

Y

JP1

4

2

3

1

65

87

76

2

4

HI

HI

LO

THERM

SWITCH

1

3

Electrical Wiring Diagram

Palermo and Bahia Domestic (60 Hz)