Palermo and bahia domestic (60 hz), Wiring diagram palermo and bahia domestic (60 hz), Page 30 – Sundance Spas Maxxus User Manual
Page 33
Page 30
OZONA
T
O
R
O
3
GRN
TB1
240 V
AC, 1 PHASE, 60 Hz
USE COPPER CONDUCT
ORS ONL
Y
WIRE SIZE MUST BE
APPROPRIA
TE
PER NEC
AND/OR LOCAL
CODES
RED
RED
BLK
WHT
WHT
RED
BLK
BLK
WHT
BLK
RED
RED
BLK
BLK
BLK
2
1
HEA
TER
5.5 kW
PRESSURE SWITCH
HI - LIMIT
/ FREEZE SENSOR
TEMPERA
TURE SENSOR
J1
J2
J3
F1
30A, 250V
SC-30
PUMP
1
PUMP
2
HOT
TUB
LIGHT
TRANSFORMER
240 V
A
C
Palermo / Bahia Panel
J4
R
Y
JP1
4
2
3
1
65
87
76
2
4
HI
HI
LO
THERM
SWITCH
1
3
Electrical Wiring Diagram
Palermo and Bahia Domestic (60 Hz)