Selecting a site – SMC Networks SMC-EZ1024DT User Manual
Page 17

S
ELECTING
A
S
ITE
5
Selecting a Site
Be sure to follow the site selection guidelines below when choosing a
location:
Select a suitable location for the switch:
•
It should be accessible for installing, cabling and maintaining the
switch.
•
The temperature and humidity should be within the ranges listed
in the specifications.
•
The status LEDs should be clearly visible.
•
There should be adequate space (approximately two inches) on all
sides for proper air flow.
Before rack mounting the switch, pay particular attention to the
following factors:
•
Temperature:
Since the temperature within a rack assembly
may be higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range.
•
Mechanical Loading:
Do not place any equipment on top of
a rack-mounted switch.
•
Circuit Overloading:
Be sure that the supply circuit to the rack
assembly is not overloaded.
•
Grounding:
Rack-mounted equipment should be properly
grounded. Particular attention should be given to supply
connections other than direct connections to the mains.
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference
such as radios and transmitters.