Installing the IP-Module

7. Place the camera body on the IP-Module and screw both units together using

the two screws supplied.

8. Connect the LAN cable to the RJ45 socket (7).
9. Connect the (12 V DC / 24 V AC) electrical supply (8).

WARNING

Ensure correct polarity if using a 12 V DC supply, as incorrect connection may
damage the dome camera or cause the unit to operate abnormally.

10. Establish communication with the device for the first time. See section 7:

Establishing initial communication with the device.

11. A test monitor can be connected to the BNC socket (6) when configuring the

camera.

12. Configure the dome camera as required. Refer to the dome camera manual for

set-up instructions.

13. Place the dome back on the camera and screw it in position.

Clean the dome after installation using a soft, lint-free cloth to remove dust and greasy finger marks.

6.2

Installing IP-Module type CVVA-IP

Fig. 2

Exploded view of IP-Module CVVA-IP

12

Siemens Building Technologies

Fire Safety & Security Products