Installation
Note
When removing the blank panels to the SRP-X500P, be
sure to start with the small panel.
Rack mounting
About the rack
Use an EIA-standard 19-inch rack with a depth of 450 mm
or more.
Use four screws of the same diameter as the rack screw
holes and with an effective length of 12 mm or more to
mount the SRP-X500P into the rack.
Note
When mounting the SRP-X500P into a rack, be sure it is
done by 2 people or more.
WRU-806 channel setting
Take the following precautions to prevent interference and
noise.
• If there is a TV broadcasting station nearby, to avoid
possible interference from its broadcasting, do not use
that station’s channel.
• When simultaneously using two or more tuners, always
set the tuners to different channels within the same group
(other than group 00).
1
Turn on the SRP-X500P.
2
Press and hold down the GP button, and press the + or
– button to select a group.
Each time you press the + or – button, the GP
indication changes as shown in the following figure.
To change the indication continuously, press and hold
down the + or – button.
The CH indication shows the lowest frequency
channel of the selected group. For group 00, however,
the channel selected last is displayed.
Rack
Screws (+B M5 X 12)
Screws (+B M5 X 12)
SRP-X500P
RF indicator
CH button
– button
+ button
GP button
GP
CH
GP
CH
GP
CH
GP
CH
GP
CH
GP
CH
Display example of WRU-806B (CE62 model)
Display example of WRU-806B (U66 model)
Display example of WRU-806A (AU66 model)