beautypg.com

Visca device setting command, 42 command list, For visca network administration – Sony EX480CP User Manual

Page 42: Visca interface command, Visca interface and inquiry

background image

42

Command List

VISCA Device Setting
Command

Before starting control of the FCB camera, be sure to
send the Address command and the IF_Clear
command using the broadcast function.

For VISCA Network Administration

Address

Sets an address of a peripheral device. Use when
initializing the network and when receiving the
network change message indicated below.

Network Change

Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.

Packet

Note

Address

88 30 01 FF

Always broadcasted.

Network Change

X0 38 FF

X = 9 to F: FCB camera address + 8

VISCA Interface Command

IF_Clear

Clears the command buffers in the FCB camera and
cancels the command currently being executed.

Command Packet Reply Packet

Note

IF_Clear

8X 01 00 01FF

X0 50 FF

IF_Clear (broadcast)

88 01 00 01 FF

88 01 00 01 FF

X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)

VISCA Interface and Inquiry

CAM_VersionInq

Returns information on the VISCA interface.

Inquiry

Inquiry Packet

Reply Packet

Description

CAM_VersionInq

8X 09 00 02 FF

Y0 50 GG GG

GGGG = Vender ID

HH HH JJ JJ

(0020: Sony)
KK FF

HHHH = Model ID
0434 = FCB-EX480C
0435 = FCB-EX480CP
0436 = FCB-EX48C
0437 = FCB-EX48CP
JJJJ = ROM revision
KK = Maximum socket # (02)

X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)