2-5. peripheral device control – Star Micronics DOT MATRIX PRINTER SP2000 User Manual
Page 33

31
1-2-5. Peripheral Device Control
FUNCTION
Defines drive pulse width for peripheral device #1
CODE
n1 n2
(1B)H (07)H
n1 n2
DEFINITION RANGE
1
<
=
n1
<
=
127, 1
<
=
n2
<
=
127 (default setting n1 = n2 = 20)
OUTLINE
Adjusts drive pulse width for peripheral devices requiring other
than standard 200 ms pulse time and delay time
Energizing time = 10 X
n1 (ms)
Delay time = 10 X
n2 (ms)
Executed by
10 x
n1 (ms)
10 x
n2 (ms)
Printing and paper
feed are prohibited.
FUNCTION
Controls peripheral device #1
CODE
(07)H
OUTLINE
Executes drive pulse for peripheral unit 1 (deferred).
NOTE