beautypg.com

Serial interface settings – Smart Technologies SMART Board 800i5-SMP User Manual

Page 84

background image

N

  N O T E

On projectors with the RS-232 connector labeled Control 9v (rather than Control), pin 1 functions

as a +9V DC power source only for use with older model ECPs such as the ones shipped with

SMART UF55 projectors.

Serial interface settings

The serial interface of the projector acts as a Data Communications Equipment (DCE) device and its

settings can’t be configured. You must configure your computer’s serial communication program

(such as Microsoft® HyperTerminal) or your room control system’s serial communication settings

with the following values:

Setting

Value

Data Rate

19.2 kbps

Data Bits

8

Parity

None

Stop Bits

1

Flow Control

None

N

  N O T E S

l

Asynchronous mode is disabled by default in the projector.

l

All commands should be in ASCII format. Terminate all commands with a carriage return.

l

All responses from the projector are terminated with a command prompt. Wait until you

receive the command prompt indicating that the system is ready for another command before

you proceed.

l

The room control feature of the projector is always on.

g

To configure your computer’s serial interface

1. Turn on your computer, and then start your serial communications program or terminal

emulation program.

2. Connect your computer to the serial connection cable you previously connected to the ECP.

A P P E N D I X

B

Remotely managing your system through an RS-232 serial interface

72

This manual is related to the following products: