Sanyo CH1852 User Manual
Page 36

32
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 / 208V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.25
/
0.23
0.49
/
0.46
6.86
/
7.41
7.6
/
8.1
Power Input
kW 0.047 / 0.045
0.113 / 0.095
1.54
/
1.52
1.70
/
1.66
Full Load Conditions Running Amps.
A
0.25
/
0.23
0.49
/
0.46
8.8
/
9.7
9.5
/
10.4
Power Input
kW 0.047 / 0.045
0.113 / 0.095
1.98
/
1.98
2.14
/
2.12
Rating Conditions
: Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor Air Temperature 115°F (46.1°C) D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 / 208V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.25
/
0.23
0.49
/
0.46
6.36
/
6.81
7.1
/
7.5
Power Input
kW 0.047 / 0.045
0.113 / 0.095
1.45
/
1.40
1.61
/
1.54
Full Load Conditions Running Amps.
A
0.25
/
0.23
0.49
/
0.46
8.6
/
9.4
9.3
/
10.1
Power Input
kW 0.047 / 0.045
0.113 / 0.095
1.94
/
1.92
2.10
/
2.06
Rating Conditions
: Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.
Indoor Unit
KHS1852
Outdoor Unit
CH1852
000-111
SM
(18-68)
00.3.17
11:49
AM
y [ W 32