the RTC can continue to operate even though VCC is removed,
provided that a sufficiently charged backup device is connected to the
VRTC. Refer to section 5.18.1 for details.
The relevant characteristics of the ON/OFF Power control interface are shown in the
table below.
Parameter
Conditions
Min
Typ
Max
Unit
Input low (0V), VCC =
3.6V -60 -25 -12 µA
Input current
Input high (VCC), VCC = 3.6V
0
1
µ
A