beautypg.com

Sony DVS-9000-C User Manual

Page 25

background image

1-17

DVS-9000/9000SF

1-8. Checks on Completion of Installation

DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) :
STATUS1 to STATUS4 LED
Used for maintenance purpose. Only the STATUS1 LED is
lit in normal operation.

DI4 (green) (B-5) :

+

+

+

+

+3.3 V

Indicates the status of the VCC (CORE) and VCC (I/O)
powers that are supplied to the CPU-DK module.

: COM CPU-1

: COM CPU-2

SW1 (D-5) : RESET switch
Pressing this switch resets the CPU-DK module.
n
In some machines in which the CPU-DK module is
installed, the system reset may be activated.

SW2 (C-5) : MODE switch
8-pin DIP switch
Used only for production in the assembly factory. All
switches are set to OFF for normal operation.
Default setting when shipped from the factory is all OFF.

: S-BUS
D1 (B-1) : SBUS RX status LED
Lit when receiving data.

: S-BUS
S1 (B-3) : RESET switch
Pressing this switch resets the IF-844 board.


E1 (B-3) : GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.

TP1 (A-2) : RX check terminal
S-BUS communication line measuring terminal.

TP2 (A-3) : TEST terminal
Terminal for testing.