beautypg.com

3 burner and nozzle data tables (90 cm models), Instructions for the installer – Smeg CB61VES User Manual

Page 10

background image

Instructions for the Installer

12

3.3 Burner and Nozzle Data Tables (90 cm Models)


Burner

Rated

heat

capacity

(kW)

BOTTLED GAS - G30/G31 30/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

heat capacity

(W)

Flow-rate

g/h G30

Flow-rate

g/h G31

Auxiliary

1

50

30

350

73

71

Semi-rapid

1.75

65

33

450

127

125

Rapid

3

85

45

800

218

214

Triple Flame

3.2

91

65

1500

233

229

Fish

1.9

68

45

800

138

136

Oven

3.2

87

48

850

233

229

Maxi oven

5.2

110

59

1200

378

371

Grill

2.9

87

//

//

218

214

Maxi grill

4.0

100

//

//

291

286


Burner

Rated

heat

capacity

(kW)

TOWN GAS – G110 8 mbar

Nozzle diameter

1/100 mm

Reduced heat capacity

(W)

Auxiliary

1

145

350

Semi-rapid

1.75

190

450

Rapid

3

260

800

Triple Flame

3.5

290

1500

Fish

1.9

190

800

G110 gas cannot be used in models with gas oven.

The data for town gas refer to category III 1a2H3+ appliances.



Burner

Rated

heat

capacity

(kW)

NATURAL GAS - G20 20 mbar

Nozzle diameter

1/100 mm

Reduced heat capacity

(W)

Auxiliary

1

72

350

Semi-rapid

1.75

97

450

Rapid

3

115

800

Triple Flame (4)

3.5

133

1500

Triple Flame (8)

3.5

140

1500

Fish

1.9

94

800

Oven

3.2

130

850

Maxi oven

5.2

164

1200

Grill

2.9

130

//

Maxi grill

4.0

150

//