beautypg.com

Connectivity rules, 1000base-t cable requirements, 10 gbps ethernet collision domain – SMC Networks TIGERSTACK II SMC8950EM User Manual

Page 50: Table 4-1, Table 4-2, Table 4-3

background image

4-6

Making Network Connections

4

Connectivity Rules

When adding hubs (repeaters) to your network, please follow the connectivity rules
listed in the manuals for these products. However, note that because switches break
up the path for connected devices into separate collision domains, you should not
include the switch or connected cabling in your calculations for cascade length
involving other devices.

1000BASE-T Cable Requirements

All Category 5 UTP cables that are used for 100BASE-TX connections should also
work for 1000BASE-T, providing that all four wire pairs are connected. However, it is
recommended that for all critical connections, or any new cable installations,
Category 5e (enhanced Category 5) or Category 6 cable should be used. The
Category 5e specification includes test parameters that are only recommendations
for Category 5. Therefore, the first step in preparing existing Category 5 cabling for
running 1000BASE-T is a simple test of the cable installation to be sure that it
complies with the IEEE 802.3-2005 standards.

10 Gbps Ethernet Collision Domain

Table 4-1 Maximum 10GBASE-SR 10 Gigabit Ethernet Cable Length

Fiber Size

Fiber Bandwidth

Maximum Cable Length

Connector

62.5/125 micron

single-mode fiber

160 MHz/km

2-26 m

(7-85 ft.)

LC

62.5/125 micron

single-mode fiber

200 MHz/km

2-33 m

(7-108 ft.)

LC

50/125 micron

single-mode fiber

400 MHz/km

2-66 m

(7-216 ft.)

LC

50/125 micron

single-mode fiber

500 MHz/km

2-82 m

(7-269 ft.)

LC

50/125 micron

single-mode fiber

2000 MHz/km

2-300 m

(7-984 ft.)

LC

Table 4-2 Maximum 10GBASE-LR 10 Gigabit Ethernet Cable Length

Fiber Size

Fiber Bandwidth

Maximum Cable Length

Connector

9/125 micron

single-mode fiber

N/A

10 km (6.2 miles)

LC

Table 4-3 Maximum 10GBASE-ER 10 Gigabit Ethernet Cable Length

Fiber Size

Fiber Bandwidth

Maximum Cable Length

Connector

9/125 micron

single-mode fiber

N/A

40 km (24.85 miles)

LC

This manual is related to the following products: