4. CHARGER AND AC POWER CORD CONNECTIONS

RISK OF ELECTRIC SHOCK OR FIRE.

The Instant Power™ charger is for use on a nominal 120-volt

circuit. The plug must be plugged into an outlet that is properly

installed and grounded in accordance with all local codes and

ordinances. The plug pins must fit the receptacle (outlet). Do not

use with an ungrounded system.

NOTE: Pursuant to Canadian

Regulations, use of an adapter plug is not allowed in Canada. Use of an adapter plug in

the United States is not recommended and should not be used.

5. INSTALLATION INSTRUCTIONS

Remove all cord wraps and uncoil the cables prior to using the Instant Power™.

6. FEATURES

1. Charged/Charging LEDs

2. Battery Status LEDs

3. Battery Status Button

4. 12V DC Power Outlet

(not shown)

1

2

3

7. CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER™

IMPORTANT: CHARGE IMMEDIATELY AFTER PURCHASE, AFTER EACH USE

AND EVERY 30 DAYS TO KEEP THE INSTANT POWER™ INTERNAL BATTERY

FULLY CHARGED.

7.1 Use of an improper extension cord to charge the Instant Power™ could result in a risk of

fire and electric shock. Make sure:

• That the pins on the plug of the extension cord are the same number, size and shape

as those of the plug on the Instant Power™.

• That the extension cord is properly wired and in good electrical condition.

• That the extension cord has a wire size of 18 gauge (AWG) [0.82 mm

2

] or larger and is

50 feet (15.24 meters) long or less.

7.2 To reduce the risk of electric shock, turn off and/or unplug the Instant Power™ before

attempting any maintenance or cleaning. Simply turning off the controls will not reduce

this risk.

7.3 When charging the internal battery, work in a well-ventilated area and do not restrict the

ventilation in any way.

7.4 LED Indicators:

To check the internal battery’s charge status, press the Battery Status button on the front

of the Instant Power™.

The LED lights will indicate the charge level as follows:

• A red LED

indicates a 50% or less charge and you should immediately recharge

the Instant Power™.

• A yellow LED

indicates a 50 to 75% charge. The Instant Power™ may be used but

should be recharged as soon as possible.

• A green LED

indicates the internal battery is fully charged.

• The CHARGING

(red) LED indicates the Instant Power™ is charging (connected

to an AC power source.) At full charge, the CHARGED

(green) LED will light.