Adjusting the airflow direction, Operation without the remote control unit, Care and cleaning – Sanyo CH3682 User Manual

Page 75: Horizontal, Vertical

background image

15

ADJUSTING THE AIRFLOW
DIRECTION

1. Horizontal

The horizontal airflow can be adjusted by moving the vertical vanes
with your hands to the left or right.

When the humidity is high, the vertical vanes should be in the
front position during the cooling or dehumidifying operation. If
the vertical vanes are positioned all of the way to the right or
left, condensation may begin to form around the air vent and
drip down.

2. Vertical

The vertical airflow can be adjusted by moving the flap with the
remote control unit. Do not move the flap with your hands. Confirm
that the remote control unit has been turned on. Use the FLAP
button to set either the sweep function or one of the six airflow
direction settings.

• The flap automatically closes when the unit is off.
• During the heating operation, the fan speed will be very low and the

flap will be in the horizontal position (position

) until the air being

blown out of the unit begins to warm. Once the air warms up, the
flap position and fan speed change to the settings specified with
the remote control unit.

• Use the FLAP button on the remote control unit to adjust the

position of the flap. If you move the flap by hand, the flap
position according to the remote control unit and the actual
flap position may no longer match. If this should happen,
shut off the unit, wait for the flap to close, and then turn on
the unit again; the flap position will now be normal again.

• Do not have the flap pointed down during cooling operation.

Condensation may begin to form around the air vent and drip
down.

OPERATION WITHOUT THE
REMOTE CONTROL UNIT

If you have lost the remote control unit or it has trouble, follow the
steps below.

When the air conditioner is not running

Each time the OPERATION button is pressed, the type of operation
conducted is indicated by the changing color of the OPERATION
lamp. Press the button and select the lamp color that suits your
preference for operation.

The temperature is set to the room temperature minus 4°F during
the cooling operation and to the room temperature plus 4°F during
the heating operation, and the fan speed and flap are set to Auto.

CARE AND CLEANING

Casing and Grille (Indoor Unit)

Clean the casing and grille of the indoor unit with a vacuum cleaner
brush, or wipe them with a clean, soft cloth.

CAUTION

HEAT
FAN

SWEEP

SWEEP

A. Sweep function

The flap starts moving
up and down to deliver
air over the sweep
range.

B. Setting the airflow manually

Referring to the above
illustration, use the
FLAP button to set the
airflow direction within
the range used during
the heating, cooling, or
dehumidifying
operation.

C. Auto flap function

The flap is set
to the
recommended
position.

COOL

DRY

NOTE

1.

For safety, be sure to turn the air
conditioner off and also to
disconnect the power before
cleaning.

2.

Do not pour water on the indoor unit
to clean it. This will damage the
internal components and cause an
electric shock hazard.

CAUTION

INDOOR UNIT

OPERATION button (ON/OFF)

OPERATION lamp

Cooling operation

(green)

Heating

operation (red)

Stop

(lamp off)

NOTE

OI-149-15-EG

01_KHS3682_EN.fm Page 15 Friday, February 12, 2010 12:42 PM