beautypg.com

3. heating capacity – Sanyo CH3682 User Manual

Page 27

background image

Indoor Unit

: KHS3082

Outdoor Unit : CH3082
Power Supply : 230V Single Phase 60Hz

< Heating Capacity >

5-3. Heating Capacity

TH : Total Heating Capacity (BTU/h)

1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.

3. Above data represents the value when the operation frequency of a compressor is fixed.

Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air

Prevention Protection during heating operation into account. For this reason, the value may vary

from the actual heating characteristics.

NOTE

RATING CAPACITY:

33,000 BTU/h

AIR FLOW RATE:

671 CFM

OUTDOOR

INDOOR

ENT. TEMP.

o

F (

o

C)

AMBIENT TEMP.

o

F (

o

C)

W.B.

60

65

70

75

80

(15.6)

(18.3)

(21.1)

(23.9)

(26.7)

0 (-17.8)

TH

18,060

18,120

18,170

18,210

18,240

3 (-16.1)

TH

18,670

18,730

18,780

18,820

18,850

8 (-13.3)

TH

20,120

20,190

20,240

20,280

20,320

13 (-10.6)

TH

21,640

21,710

21,770

21,810

21,840

18 (-7.8)

TH

23,320

23,390

23,450

23,500

23,530

23 (-5.0)

TH

25,100

25,170

25,230

25,280

25,310

28 (-2.2)

TH

26,960

27,030

27,090

27,140

27,160

33 (0.6)

TH

28,900

28,970

29,030

29,070

29,090

38 (3.3)

TH

30,830

30,900

30,950

30,990

30,500

43 (6.1)

TH

32,880

32,950

# 33,000

33,030

30,830

48 (8.9)

TH

34,980

35,050

35,090

35,120

31,060

53 (11.7)

TH

37,120

37,180

37,220

35,460

31,180

58 (14.4)

TH

39,210

39,260

39,280

35,480

31,180

63 (17.2)

TH

41,380

41,410

40,090

35,340

31,050

65 (18.3)

TH

42,230

42,260

39,980

35,250

30,960

27

This manual is related to the following products: