DATASHEET

17.6

ALTINT

Alternate Interrupt Mode.
0 = Primary interrupt system enabled (Default).
1 = Alternate interrupt system enabled.
See

Section 5.2, "Interrupt Management," on page 48

.

RW

0

17.5:4

Reserved

Write as 0, ignore on read.

RW

00

17.3

PHYADBP

1 = PHY disregards PHY address in SMI access

write.

RW

0

17.2

Force

Good Link Status

0 = normal operation;
1 = force 100TX- link active;

Note:

This bit should be set only during lab testing

RW

0

17.1

ENERGYON

ENERGYON – indicates whether energy is detected
on the line (see

Section 5.3.5.2, "Energy Detect

Power-Down," on page 51

); it goes to “0” if no valid

energy is detected within 256ms. Reset to “1” by
hardware reset, unaffected by SW reset.

RO

X

17.0

Reserved

Write as 0. Ignore on read.

RW

0

Table 5.30 Register 18 - Special Modes

ADDRESS

NAME

DESCRIPTION

MODE

DEFAULT

18.15

Reserved

Write as 0, ignore on read.

RW

0

18.14

Reserved

Write as 1, ignore on read.

RW,

NASR

1

18.13:8

Reserved

Write as 0, ignore on read.

RW,

NASR

000000

18.7:5

MODE

Transceiver Mode of operation. Refer to

Section

5.3.9.2, "Mode Bus – MODE[2:0]," on page 53

for

more details.

RW,

NASR

XXX

18.4:0

PHYAD

PHY Address.
The PHY Address is used for the SMI address and for
the initialization of the Cipher (Scrambler) key. Refer
to

Section 5.3.9.1, "Physical Address Bus -

PHYAD[0]," on page 53

for more details.

RW,

NASR

PHYAD

Table 5.31 Register 26 - Symbol Error Counter

ADDRESS

NAME

DESCRIPTION

MODE

DEFAULT

26.15:0

Sym_Err_Cnt

100Base-TX receiver-based error register that
increments when an invalid code symbol is received
including IDLE symbols. The counter is incremented
only once per packet, even when the received packet
contains more than one symbol error. The 16-bit
register counts up to 65,536 (2

16

) and rolls over to 0

if incremented beyond that value. This register is
cleared on reset, but is not cleared by reading the
register. It does not increment in 10Base-T mode.

RO

0

Table 5.29 Register 17 - Mode Control/Status (continued)

ADDRESS

NAME

DESCRIPTION

MODE

DEFAULT