beautypg.com

Troubleshooting, Also available from seco-larm – SECO-LARM USA Delayed Egress Timer SA-025EQ User Manual

Page 12

background image

ENFORCER Delayed Egress Timer

12

SECO-LARM U.S.A., Inc.

NOTICE The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy

is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2012 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without
the written permission of SECO-LARM.

WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a
period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused

by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty
installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other
than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to
replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or
consequential personal or property damages of any kind to the purchaser or anyone else.

Order Part #763-021-3%

MiSA-025EQZZ_1210.docx

PITSW1

SECO-LARM U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606

Website: www.seco-larm.com

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326

E-mail: [email protected]

IMPORTANT Users and installers of this product are responsible for ensuring this product complies with all national, state, and local laws,
statutes, and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of
any current laws, statutes, or codes.

Troubleshooting:

Initiate device (such as a push-to-exit bar)
will not release the lock

Check the nuisance delay.
See pg. 6, Nuisance Delay.

Check the pre-delay timer.

See pg. 6, Adjusting the Pre-Delay and

Post-Delay.

Check the security mode.

See pg. 7, Security Mode Jumper.

Door will not relock

Check the relock mode.

See pg. 5, Relock Modes.

Check the bypass input.

See pg. 8, Bypass Input.

Door automatically relocks in BOCA mode.

Check the lock status.

See pg. 7, Lock Status Jumper.