Roubleshooting – Southbend SIMPLE STEAM COUNTERTOP STEAMERS EZ-5 User Manual
Page 25
M
ODEL
EZ-3
&
EZ-5
C
OUNTERTOP
S
TEAMERS
T
ROUBLESHOOTING
O
PERATOR
’
S
M
ANUAL
1178387
P
AGE
25
T
R
O
U
B
L
E
S
H
O
O
T
IN
G
Figure 14
Idle Element Resistance Check (for units built before January 15, 2001)
Idle Element Plug
Model EZ-3
Model EZ-5
High Limit
1. Disconnect power at circuit breaker.
2. Remove control panel.
3. Disconnect idle element plug (PL3).
4. Place test leads as shown above.
5. Check to see if resistance is within +/- 10% of values in the following table:
Voltage
Model EZ-3
Resistance (Ohms)
Model EZ-5
Resistance (Ohms)
208
115
87
220
129
97
240
154
115
380
385
289
415
459
344
480
614
461
6. Remove one test lead, place on ground, check for short circuit.
This manual is related to the following products: