beautypg.com

Roubleshooting – Southbend SIMPLE STEAM COUNTERTOP STEAMERS EZ-5 User Manual

Page 25

background image

M

ODEL

EZ-3

&

EZ-5

C

OUNTERTOP

S

TEAMERS

T

ROUBLESHOOTING

O

PERATOR

S

M

ANUAL

1178387

P

AGE

25

T

R

O

U

B

L

E

S

H

O

O

T

IN

G

Figure 14

Idle Element Resistance Check (for units built before January 15, 2001)

Idle Element Plug

Model EZ-3

Model EZ-5

High Limit

1. Disconnect power at circuit breaker.

2. Remove control panel.

3. Disconnect idle element plug (PL3).

4. Place test leads as shown above.

5. Check to see if resistance is within +/- 10% of values in the following table:

Voltage

Model EZ-3

Resistance (Ohms)

Model EZ-5

Resistance (Ohms)

208

115

87

220

129

97

240

154

115

380

385

289

415

459

344

480

614

461

6. Remove one test lead, place on ground, check for short circuit.