Figure 6

Unit Using Excessive Amount of Water and/or Excessive Steam Coming from
Vent Tube



Figure 7

“Check Water Level” Light Does Not Come On When Unit Runs Out of Water

Unit using excessive amount of water and/or excessive steam

coming from vent tube behind the unit.

No

Yes

Excessive steam?

DISCONNECT POWER AT CIRCUIT BREAKER

Remove control panel, but leave plug connected.

Disconnect wire between float switch and controller (see applicable

wiring diagram), reconnect power, turn unit on, and wait 12 minutes.

DISCONNECT POWER AT CIRCUIT BREAKER

Check controller (see Figure 22 on page 33). Replace as

necessary. (On EZ-3 units built before Jan. 15, 2001, also

check Time Delay Relay, see Figure 21 on page 32.)

Check float switch and float tube. Replace float switch and

clean float tube as necessary (see Figure 18 on page 29).

Check contactor and replace

as necessary (see Figure 13

on page 24).

Reinstall control panel,

reconnect power.

DISCONNECT POWER AT CIRCUIT BREAKER

Reconnect power.

Wait 12 minutes.

No

Yes

Excessive steam?

“CHECK WATER LEVEL” light does not come on when unit

runs out of water.

No

Yes

Is resistance over

100 Kohm?

Remove wire C53 from “CHECK WATER LEVEL” light and check

resistance across light terminals.

Check high limits (see Figure 20 on page 31)

and replace as needed.

Replace light.