beautypg.com

Roubleshooting, Ez-3, Ez-5 – Southbend SIMPLE STEAM COUNTERTOP STEAMERS EZ-5 User Manual

Page 17: Figure 5

background image

M

ODEL

EZ-3

&

EZ-5

C

OUNTERTOP

S

TEAMERS

T

ROUBLESHOOTING

O

PERATOR

S

M

ANUAL

1178387

P

AGE

17

T

R

O

U

B

L

E

S

H

O

O

T

IN

G

Figure 5

Unit Not Heating Up Properly or Not Cooking As Fast, “ON” Light Lit

Is “CHECK WATER LEVEL”

light on with door closed?

Check all main fuses or circuit breaker, replace as necessary.

Unit not heating up properly, or not cooking as fast, “ON” light lit.

No

Yes

Drain unit. Turn unit on with door open. Add two gallons of
water THROUGH TROUGH. Close door. Wait 10 minutes.

Open door. Depress and

hold door switch.

For EZ-3 units built before

Jan. 15, 2001, check and

replace time delay relay as

necessary (see Figure 21on

page 32).

Does unit have water?

Add water according to start-

up instructions on door. Wait

5 minutes, light should go off.

Is bottom of unit covered

with deposits?

Check high limits and replace

as necessary (see Figure 19

on page 30 or Figure 20 on

page 31, as applicable).

If high limits are OK, check

that heater block mounting

bolts are tightened to 75 inch-

pounds.

Clean unit (see page 13).

DISCONNECT POWER

AT CIRCUIT BREAKER

Does unit heat up?

Remind operator of proper

filling procedure.

DISCONNECT POWER

AT CIRCUIT BREAKER.

Remove door switch lead

wires from terminal block

positions 2 and 3.

Remove control panel.

Depress door switch and

check door switch lead wires

for continuity (see Figure 16

on page 27 or Figure 17 on

page 28, as applicable).

Yes

No

Yes

No

No

Yes

Does contactor “click”

on and stay on for at least 1

minute?

DISCONNECT POWER

AT CIRCUIT BREAKER.

Check resistance between

contactor terminals and

replace any bad elements

(see Figure 10 on page 21).

No

Yes

Replace door switch.

Continuity?

Replace float switch and

clean tube.

Float switch and float

tube OK?

Remove rear cover

Reconnect door switch lead wires.

Check float switch for continuity

and clean openings in float tube

(see Figure 18 on page 29).

Check and replace contactor

(see Figure 13 on page 24)

and controller (see Figure 22

on page 33).

No

Yes

No

Yes

This manual is related to the following products: