D1 (A-3) :
+
+
+
+
+12 V
+12 V power supply status indication.
Lit when the
+12 V power is supplied.
If this LED does not light, the fuse may have blown.
D2 (A-4) :
+
+
+
+
+3.3 V
+3.3 V power supply status indication.
Lit when the
+3.3 V power is supplied.
D3 (A-4) :
+
+
+
+
+2.5 V
+2.5 V power supply status indication.
Lit when the
+2.5 V power is supplied.
D5 (A-5) : CONF1 status LED
H2 to L2 FPGA (Spartan II) CONFIG DONE status
indication.
Not lit when configuration is completed.
D6 (A-5) : CONF2 status LED
D10 to L10 FPGA (Spartan II) CONFIG DONE status
indication.
Not lit when configuration is completed.
S1 (A-6) : DI reset switch
CN1 (A-6) : ISP common connector
program writing into the JTAG device with ISP.
E1 (C-6), E2 (J-2), E3 (P-5), E4 (B-11), E5 (H-11), E6 (N-8),
E7 (A-7) : GND terminal bard
respective check terminals.
1-8. Checks on Completion of Installation