M1051 6" Bench Grinder

SAFETY

ELECTRICAL

This equipment must be grounded.

Verify that any existing electrical out-

let and circuit you intend to plug into

is actually grounded. If it is not, it

will be necessary to run a separate 12

A.W.G. copper grounding wire from

the outlet to a known ground. Under

no circumstances should the ground-

ing pin from any three-pronged plug

be removed or serious injury may

occur.

110V Operation

When it is necessary to use an extension cord, use the

following guidelines:

Use cords rated for standard service.

Never exceed a length of 100 feet.

Use cords with 14 ga. wire or bigger.

Insure cord has a ground wire and pin.

Do not use cords in need of repair.

Extension Cords

Grounding

This machine must be grounded

! The electrical cord sup-

plied with the Model M1051 comes with a grounding pin.

Do not remove it (see

Figure 2). If your outlet does not

accommodate a ground pin, have it replaced by a quali-

fied electrician or have an appropriate adapter installed.

Note: When using an adapter, the adapter must be

grounded.

The SHOP FOX

®

M1051 operates at 110 volts. The motor

supplied with this machine is rated at

1

3

HP. When

choosing an outlet for this machine, consider using one

with a 15 amp circuit breaker or fuse. Keep in mind that

a circuit being used by other machines or tools at the

same time will add to the total load being applied to the

circuit. Add up the load ratings of all machines on the

circuit. If this number exceeds the rating of the circuit

breaker or fuse, use a different circuit.

Figure 2. Never remove the grounding

pin!