VENT DAMPERS

A Slant/Fin vent damper is available only as part of a
Slant/Fin gas boiler package equipped with a 24 volt
gas valve. This vent damper is design certified by A.G.A.
for use only on specific Slant/Fin Corporation gas boiler
models.

These boilers will be equipped with a plate which states
that the boiler may be used with a Slant/Fin Corp. auto-
matic vent damper device and indicates the proper vent
damper model number.

OTHER VENT DAMPER OR DEVICES WITH SIMILAR
PURPOSE ARE NOT PERMITTED.

WITH ANY VENT DAMPER
OR PILOT SYSTEM

(a) DO NOT attempt to install or adjust or service it

yourself.

(b) Make certain that the installation is approved by your

local gas utility.

IGNITION SYSTEM—CONTINUOUS
BURNING (STANDING) PILOT

Your gas boiler is equipped with the Honeywell VR8200
or VR8300 gas valves. See Safety and Lighting
Instructions on pages 7 and 8 and Figure 22.

SAFETY AND LIGHTING INSTRUCTIONS

FOR IGNITION SYSTEMS EQUIPPED WITH GAS

VALVES VR8200 AND VR8300

SAFETY INFORMATION

For Your Safety Read Before Lighting

WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by

hand. When lighting the pilot, follow these instruc-
tions exactly.

Your gas boiler must be installed and serviced by a qualified service agency or

gas supplier. The lack of proper service can result in a dangerous condition.

WARNING

Should overheating occur or the gas supply fail to shut off, DO NOT turn

off or disconnect the electric supply to the circulator pump. Instead,

shut off the gas supply at a location EXTERNAL to the appliance.

7

Figure 22. Continuous (Standing) Pilot

Ignition System