11

closed water systeMs

Water supply systems may, because of code requirements or such

conditions as high line pressure, among others, have installed

devices such as pressure reducing valves, check valves, and

back flow preventers. Devices such as these cause the water

system to be a closed system.

therMal eXpansIon

As water is heated, it expands (thermal expansion). In a closed

system the volume of water will grow when it is heated. As the

volume of water grows there will be a corresponding increase in

water pressure due to thermal expansion. Thermal expansion

can cause premature tank failure (leakage). This type of failure

is not covered under the limited warranty. Thermal expansion

can also cause intermittent pressure relief valve operation: water

discharged from the valve due to excessive pressure build up.

This condition is not covered under the limited warranty. The

pressure relief valve is not intended for the constant relief of

thermal expansion.

A properly sized thermal expansion tank should be installed

on all closed systems to control the harmful effects of thermal

expansion. Contact a local plumbing service agency to have a

thermal expansion tank installed.