AJ-44C Series Technical Manual 7610-001-76-22
Issued: 03-21-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
OPERATING CHARACTERISTICS
2
RACKS PER HOUR:
AJ-44-66-80CE/CS/CGP
248
AJ-44-66-80CEL/CSL
234
DISHES OR GLASSES PER HOUR:
AJ-44-66-80CE/CS/CGP
6200
AJ-44-66-80CEL/CSL
5850
PREWASH TANK CAPACITY (GALLONS):
AJ-66CE/CEL/CS/CSL/CGP
16
AJ-80CE/CEL/CS/CSL/CGP
16
WASH TANK CAPACITY (GALLONS):
AJ-44-66-80CE/CS/CGP
15.4
PREWASH PUMP CAPACITY (GPM):
AJ-66CE/CEL/CS/CSL/CGP
120
AJ-80CE/CEL/CS/CSL/CGP
270
WASH PUMP CAPACITY
GALLONS PER MINUTE (ALL MODELS):
270
VENTING REQUIREMENTS (CFM)(100% CAP.):
INPUT END
200
OUTPUT END
400
TOTAL
600
CONVEYOR SPEED (FPM):
AJ-44-66-80CE/CS/CGP MACHINES
6.9
AJ-44-66-80CEL/CSL MACHINES
6.5
GALLONS PER RACK:
AJ-44-66-80CE/CS/CGP MACHINES
.94
AJ-44-66-80CEL/CSL MACHINES
1.00
WATER TEMPERATURES:
AJ-44-66-80CE/CS/CGP MODELS:
PREWASH (RECOMMENDED)
110-140
°F
WASH (MINIMUM)
160
°F
RINSE (MINIMUM)
180
°F
AJ-44-66-80CEL/CSL MODELS:
PREWASH (RECOMMENDED)
110-140
°F
WASH (MINIMUM)
140
°F
RINSE (MINIMUM)
140
°F
FLOW PRESSURE (PSI)
20
±5
FLOWRATE (GPM):
AJ-44-66-80CE/CS/CGP
3.9
AJ-44-66-80CEL/CSL
3.9
MINIMUM CHLORINE (PPM)
AJ-44-66-80CEL/CSL MODELS ONLY:
50
STEAM COIL TANK HEAT (CS/CSL MODELS ONLY):
STEAM INLET PRESSURE (PSIG)
10-20
STEAM CONNECTION NPT
3/4”
CONSUMPTION @ 15 PSIG (lbs/hr):
AJ-44-66-80CS/CSL
60
MOTOR ELECTRICAL CHARACTERISTICS:
DRIVE MOTOR HP
1/4
WASH MOTOR HP
2
POWER RINSE MOTOR HP
2
PREWASH MOTOR HP:
AJ-66 MODELS
1
AJ-80 MODELS
2
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec-
tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim-
ply for reference and may change without notice at any
given time.