Data i/o, Installing the ferrite core, Connections – JVC RM-P2580 User Manual
Page 24: Rear panel connectors (continued)
![background image](/manuals/134140/24/background.png)
24
4. CONNECTIONS
REAR PANEL CONNECTORS (Continued)
DATA I/O
Ⅵ
ALARM INPUTS 1 to 16
TTL level (Make/Break), input duration 70 ms or more.
REF. : “CONTROL UNIT SCREEN” on page 28 and
“POLARITY item of DATA I/O SCREEN (INPUT
ASSIGNMENT SCREEN)” on page 31 for the Make/
Break switching.
Ⅵ
ALARM/SELECT OUTPUTS 1 to 16
Alarm or selection output.
Open-collector output of a LOW pulse for between 500 ms
and 1000 ms.
Max. voltage 30 V, current 30 mA.
Ⅵ
UNIT ALARM
Open-collector, LOW output during the alarm time period.
Maximum voltage, 30 V, current 30 mA.
Ⅵ
CAM SW
●
Connect to the CAM SW OUT (camera switching signal
output) terminal of the time-lapse VCR. Time-lapse re-
cording is not available if this connection is not made.
●
Set “polarity” according to the VCR to be used. When
using a JVC time-lapse VCR, set to “LOW”.
REF. : “CONTROL UNIT SCREEN” on page 28 and “CAM
SWITCH item of DATA I/O SCREEN” on page 30.
REF. : “DATA I/O SCREEN” on page 30 for the input/output signal switching.
DATA I / O
COM
1
2
3
4
5
6
7
8
COM 9/1
9/1 10/2
10/2 11/3
11/3 12/4
12/4 13/5
13/5 14/6
14/6 15/7
15/7 16/8
16/8 COM
COM
COM
CAMERA
SW
SW
UNIT
ALARM
ALARM
AUTO
HOLD
Install a ferrite core on cables connected to the DATA I/O ter-
minals and to the TO CAMERA terminals as shown in the dia-
gram on the left. Keep the ferrite core as close as possible to
the remote control unit.
Installing the Ferrite Core