Electrical Connections
All electrical connections must
be done by a qualified electri-
cian. All adjustments or repairs must be done
with the dust collector disconnected from the
power source, unplugged. Failure to comply may
result in serious injury!
The DC-1200BK/CK dust collectors are rated at 230V
Only
. The DC-1200 is not supplied with a plug. Use a
plug and outlet rated at least 20 amps. The circuit for
the machine should also be protected by at least a 20
amp circuit breaker or fuse.
The DC-1200BK-3 and DC-1200CK-3 are rated at 3
Phase 230V/460V, Prewired 230V. If you want to
run these on 460V refer to the wiring diagram found
on the inside of the switch box cover.
Keep in mind that a circuit being used by other
machines, tools, lights, heaters, etc. at the same time
will add to the electrical load. A dedicated circuit to
the dust collector will give you the best results since
dust collectors are generally used at the same time
other tools are running.
Turning the Machine On & Off
This machine is intended for
indoor use only.
All Models
Before hooking up to the power source, make sure
that the switch is in the off position.
Turn the dust collector on by pressing the Start
button mounted next to the motor. Press the Stop
button to turn off the dust collector.
Remote Control (Optional Accessory)
The DC-RC230 RF Remote Power Control unit is
available as an optional accessory (contact Customer
Service by calling the number on the cover).
Important:
The DC-RC230 Remote Power Control
can be used for activating Dust Collection units
powered by 230V only up to 3HP, single phase
only
.
Figure 13A Figure 13B
Dust Collector RF Remote
Power Control (optional)
The DC-RC230 Remote Power Control (Figure 14)
should be used for activating Dust Collection units
powered by 230V only up to 3HP, 1 Phase. The DC-
RC230 Remote Power Control unit is rated at 230V,
Single Phase
only. Use an outlet rated at least
20amps. The circuit for the device being controlled by
the DC-RC230 should also be protected by at least a
20 amp circuit breaker or fuse.
Before hooking up to the power source, make sure
that the switch is initially in the off position on both
the dust collector and remote control unit (Figure 13).
Turning the DC-RC230
On & Off
This machine is intended for
indoor use only.
1. Plug the dust collector into the main unit
(Figure 14) and plug the main unit into the power
outlet.
To start a machine or device:
2. Turn the machine itself on.
3. On the main unit place the switch to the ON
position (Figure 13A). The red LED on the main
unit should light up.
4. Press the button on the remote control
transmitter
(Figure 14) to turn the machine on.
5. To stop the machine, press the button on the
remote control transmitter
again.
Figure 14
When the machine is running, it can be stopped by
placing the switch on the main unit in the off position