beautypg.com

Common problems – Jackson JP-24BPNSU User Manual

Page 22

background image

14

SECTION 4: TROUBLESHOOTING SECTION

COMMON PROBLEMS

Problem: Rinse water not at required temperature range.

1. Thermometer is defective. Replace.
2. Thermostat is defective. Adjust the thermostat. Replace if necessary.

Problem: Machine doesn’t drain when “OFF/DRAIN” switch is pressed.

1. Drain solenoid clogged. Remove obstruction.
2. Defective “OFF/DRAIN” switch. Replace.
3. Defective motor or motor start relay. Replace.
4. Defective drain solenoid. Replace.
5. Defective timer. Replace.

Problem: No indication of pressure.

1. Water turned off. Turn water on.
2. 1/4” test cock ball valve is closed. Open the ball valve.

JP-24BPNSU Technical Manual

7610-002-38-50 Rev. D (11/11/2005)