beautypg.com

Specifications, Back front left end right end – Jacuzzi Finestra FL61000 User Manual

Page 5

background image

Jacuzzi Whirlpool Bath: finestra Walk-in Bath

Page

fl61000B • 10/07

sPeCiFiCations

Important: Read complete instructions before beginning installation.

Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly, heater, plumbing, and fittings

necessary for whirlpool operation. A rotary drain/overflow kit is provided for installation on the bath, and an optional remote drain/

overflow assembly is also available.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made.

Do not lift

the bath by the plumbing at any time; handle by the shell only or the aluminum handles provided at the ends of the unit.
Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the finish, do not

install the bath. Damage or defect to the finish claimed after the bath is installed is excluded from the warranty. Jacuzzi Whirlpool

Bath’s responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims for

damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty information packed with

the product.
All bath units are factory tested for proper operation and watertight connections prior to shipping.
note: Prior to installation, the bath must be filled with water and operated to check for leaks that may have resulted from shipping

damage or mishandling. Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered, repaired, or

avoided by following this inspection and testing procedure.

* Add 1/4" to this dimension when roughing-in for 3-wall niche.
For all Units: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit ( See page 7 to 12).
note: 1. Measurements inside each unit represent cutout in floor to allow for drain/overflow.

2. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.

3. Service access dimensions given are minimum size.

4. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6.4 mm).

Model

Dimensions

Drain/Overflow

Dimensions

Cutout

total Weight/Floor

loading

operating

gallonage

Product

Weight

skirt/

Mounting

Heater

Finestra™ 6030
LH, RH

60” (1524 mm) L
30” (762 mm) W
38-1/2” (952.5) H

15” (381 mm) A
11-11/16” (297 mm) B

See

below

1038 lb (472 kg),

41.5 lb/ft

2

(202 kg/m

2

)

55 gal (208 liter) min,

75 gal (284 liter) max

See pages

6 to 11

Integral

Factory

installed

Finestra™ 6036
LH, RH

60” (1524 mm) L
36” (914 mm) W
38-1/2” (952.5) H

18” (457 mm) A
11-11/16” (297 mm) B

See

below

1177 lb (535 kg),

47.1 lb/ft

2

(229 kg/m

2

)

55 gal (208 liter) min,

85 gal (321 liter) max

See pages

6 to 11

Integral

Factory

installed

DRAIN/OVERFLOW

A

B

BACK

FRONT

LEFT END

RIGHT END

L

H

W

14"

1-1/2"

2"

6-1/2"

29-1/2"

16-3/4"

17-1/2"

13-3/4"

Service Access

Service
Access

sPeCiFiCations

lH=left Hand, rH=right Hand

11-11/16"

11-11/16"