If you fit your own plug, the colours of the wires in the mains lead
of your appliance may not correspond with the markings
identifying the terminals in your plug.

Proceed as follows:
1.
Connect the Green and Yellow (earth) wire to the terminal

in the plug which is marked with the letter "E" or the earth
symbol

or coloured green and yellow.

2. Connect the Blue (neutral) wire to the terminal in the plug

which is marked with the letter "N" or coloured black.

3. Connect the Brown (live) wire to the terminal in the plug

which is marked with the letter "L" or coloured red.

4. Upon completion there must be no cut, or stray strands of

wire present and the cord clamp must be secure over the
outer sheath.

The plug must not be used if the fuse cover/carrier is lost.The
cover/carrier is indicated by the coloured insert at the base of
the plug.

A replacement cover/carrier must be obtained from your local
Service Force centre. Please contact our extended warranty
administrators see page 25.

WARNING:

A cut off plug inserted into a 13 amp socket is a
serious safety (shock) hazard. Ensure that the cut
off plug is disposed of safely.

The plug must still be accessible after
the appliance has been installed.

The appliance should not be connected
to the electrical supply by means of an
extension cable.

Permanent connection

In the case of permanent connection it is necessary that you
install a double pole switch between the appliance and the
electricity supply (mains), with a minimum gap of 3mm between

the switch contacts and of a type suitable for the required load in
compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at
any point.

Any electrical work required to install this appliance should be
carried out by a qualified electrician or competent person.

WARNING:THIS APPLIANCE MUST BE
EARTHED.

Important!
If the mains supply cable is damaged it
must be replaced; contact our warranty
administrators see page 25.

The manufacturer declines any liability
should this safety measure not be
observed.

Before switching on, make sure the electricity supply voltage is
the same as that indicated on the appliance’s rating plate.The
rating plate is located on the side of the dishwasher’s door.

The plug moulded onto the lead incorporates a 13amp BSI362
fuse. Only ASTA or BSI fuses should be used.

To isolate the dishwasher from mains, remove the mains plug.

If the plug that is fitted to your appliance is not suitable for the
socket, it must be cut off and the appropriate plug fitted.

Important
The wires on the mains lead are coloured in accordance with the
following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

Electrical connection

9