beautypg.com

0 j-320/j-330/j-340 circuit diagram (60hz), Page 42 – Jacuzzi 2003+ User Manual

Page 46

background image

Page 42

Optional Stereo

And Power

Supply on J-340 Models Only

.

Power Supply

OZONA

T

OR (OPTIONAL)

O

3

GRN

TB1

Standard 240 V

AC, 3-W

ire Connection (60Hz, 1-Phase Service)

USE COPPER CONDUCT

ORS ONL

Y

. WIRE SIZE MUST

BE

APPROPRIA

TE PER NEC

AND/OR LOCAL

CODES

RED

RED

J6

BLK

J5

WHT

WHT

WHT

WHT

RED

BLK

BLK

BLK

BLK

WHT

BLK

RED

RED

BLK

BLK

BLK

2

1

FLOW SWITCH

HI - LIMIT

/ FREEZE SENSOR

TEMPERA

TURE SENSOR

J1

J2

J3

F1

30A, 250V

SC-30

PUMP

1

PUMP

2

TRANSFORMER

240 V

A

C

J4

F1

JP1

4

2

3

1

65

87

76

2

4

HI

HI

LO

C

Control Panel

CIRC.

PUMP

SP

A

LIGHT

J20

K1

K2

K3

K4

K5

K6

K7

K8

J21

J1

1

J12

J13

J14

J15

J16

J17

J18

J19

J7

J8

J9

J10

Logic Jumper Settings (Factory Defaults Shown)

JP1 1-2 ON = 30A

Logic

JP1 1-2 OFF = 50A

Logic (Factory Default Setting)

JP1 3-4 ON = 2 Pump Operation

JP1 3-4 OFF = 1 Pump Operation

JP1 5-6 ON = 60A

Logic (Remove JP1 1-2 Jumper)

JP1 5-6 OFF = Leave Of

f for 30A

or 50A

Logic

JP1 7-8 ON = ¡C

T

emperature Display

JP1 7-8 OFF = ¡F

T

e

mperature Display

This device complies with Part 15 of the

FCC rules. Operation is subject to the

following two conditions:

1.

This device may not cause harmful

interference.

2.

This device must accept any inteference

received including interference that may

cause undesired operation.

Heater

5.5 kW

240 V

A

C

16.0 J-320/J-330/J-340 Circuit Diagram (60Hz)

This wiring diagram is used for all J-320, J-330, J-340 US/Canada 240 VAC
(60Hz) dedicated power models.