• This error will cause the heater to deactivate. The main pump #1 may

also deactivate.

• This problem is caused by an interruption in water flow from an

excessively dirty filter cartridge, an “air lock” condition at the pump
intake, or by a malfunctioning flow switch.

To Correct Condition:
1. Check for proper water level. Water should be 1” below lowest pillow.
2. Check for clogged/excessively dirty circulation pump filter cartridge

(control panel side). See section 11.1, Page 30.

3. Purge “air lock” from circulation pump intake by removing its filter

cartridge (control panel side). Place your garden hose over the heater
return wall fitting near the underwater spa light (sec. 8.2, page 15).
Turn-on water for 30 seconds, then turn off. Reinstall filter cartridge and
check spa. See section 11.1, page 30.

3. If problem persists, contact your authorized dealer.

13.6 Panel displays COL

Cool Condition - Temperature has dropped 20 °F (11 °C) below
the current set temperature. The pump and heater have been
activated to bring the temperature to within 15 °F (8 °C) of
the set temperature. No corrective action is required. Note:
during cold periods, you may consider increasing the number
of filtration cycles.

13.7 Panel displays ICE

Freeze Protection - A potential freeze condition has been
detected. No action is required. Main pump will operate
to circulate warm water through the plumbing until the spa
is out of danger.

13.8 Panel displays - - -

The safety “Watchdog” software has been triggered and the
spa is deactivated. A problem has been detected which could
cause damage to the spa or its components. Contact your
authorized dealer.