Us / canada j-340 2-pump model (60hz), Export j-310 / j-320 / j-330 1-pump models (50hz), Export j-340 2-pump model (50hz) – Jacuzzi 2003+ User Manual
Page 13
Export J-310 / J-320 / J-330 1-Pump Models (50Hz)
230V/20A*
230V/30A**
Voltage:
230 VAC
230 VAC
# of Wires:
3
3
Frequency:
50Hz
50Hz
Current Draw:
15A
21A
Circuit Breaker:
20A
30A
*
In the 20A configuration, the heater will not operate at the same time
as the main jets pump. This is the factory setting.
** In the 30A configuration, the heater will operate at the same time as
the main jets pump.
Export J-340 2-Pump Model (50Hz)
230V/20A*
230V/30A**
230V/40A***
Voltage:
230 VAC
230 VAC
230 VAC
# of Wires:
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A
30A
40A
*
In 20A configuration, the heater will not operate while either jets pump
is running in high speed. This is the factory setting. Note: pump 2
runs only in high speed.
** In 30A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater will operate while either jets pump is
running in high speed. Note: pump 2 runs only in high speed.
US / Canada J-340 2-Pump Model (60Hz)
240V/50A*
240V/30A**
240V/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
36A
24A
43A
Circuit Breaker:
50A, 2-Pole
30A, 2-Pole
60A, 2-Pole
*
In 50A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
** In 30A configuration, the heater will not operate while either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** In 60A configuration, the heater will operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.
Page 9