US / Canada J-310 1-Pump Convertible Model (60Hz)
120V/15A*
240V/30A*
240V/40A**
Voltage:
120 VAC
240 VAC
240 VAC
# of Wires:
3 (15A GFCI Cord)
4
4
Frequency:
60Hz
60Hz
60Hz
Current Draw:
12A
21A
30A
Circuit Breaker:
15A, 1-Pole
30A, 2-Pole
40A, 2-Pole
For 240 VAC Heater Operation: Move the red wire on the main terminal
strip (TB1) from position #1 to position #3. Make certain wires are connect-
ed exactly as shown in Figure-D (Page 12) before applying power. Failure to
do so will result in damage to the circuit board and/or related components
and void the manufacturer’s warranty.
*
In the 15A/30A configuration, the heater will not operate at the same
time as the high-speed jets pump. The factory setting is 120V/15A.
** If the spa is to be operated on 40A service, remove the jumper JP1
#1-2 on the circuit board to allow the heater to operate at the same
time as the high-speed jets pump (Page 44).
US / Canada J-320 / J-330 1-Pump Models (60Hz)
240V/50A*
240V/30A**
Voltage:
240 VAC
240 VAC
# of Wires:
3
3
Frequency:
60Hz
60Hz
Current Draw:
34A
24A
Circuit Breaker:
50A, 2-Pole
30A, 2-Pole
* In the 50A configuration, the heater will operate at the same time as the
high-speed jets pump. This is the factory setting.
** In the 30A configuration, the heater will not operate at the same time as
the high-speed jets pump.
5.0 Power Requirements