beautypg.com

0 power requirements, Us / canada j-310 1-pump convertible model (60hz), Us / canada j-320 / j-330 1-pump models (60hz) – Jacuzzi 2003+ User Manual

Page 12

background image

US / Canada J-310 1-Pump Convertible Model (60Hz)

120V/15A*

240V/30A*

240V/40A**

Voltage:

120 VAC

240 VAC

240 VAC

# of Wires:

3 (15A GFCI Cord)

4

4

Frequency:

60Hz

60Hz

60Hz

Current Draw:

12A

21A

30A

Circuit Breaker:

15A, 1-Pole

30A, 2-Pole

40A, 2-Pole

For 240 VAC Heater Operation: Move the red wire on the main terminal
strip (TB1) from position #1 to position #3. Make certain wires are connect-
ed exactly as shown in Figure-D (Page 12) before applying power. Failure to
do so will result in damage to the circuit board and/or related components
and void the manufacturer’s warranty.

*

In the 15A/30A configuration, the heater will not operate at the same
time as the high-speed jets pump. The factory setting is 120V/15A.

** If the spa is to be operated on 40A service, remove the jumper JP1

#1-2 on the circuit board to allow the heater to operate at the same
time as the high-speed jets pump (Page 44).

US / Canada J-320 / J-330 1-Pump Models (60Hz)

240V/50A*

240V/30A**

Voltage:

240 VAC

240 VAC

# of Wires:

3

3

Frequency:

60Hz

60Hz

Current Draw:

34A

24A

Circuit Breaker:

50A, 2-Pole

30A, 2-Pole

* In the 50A configuration, the heater will operate at the same time as the

high-speed jets pump. This is the factory setting.

** In the 30A configuration, the heater will not operate at the same time as

the high-speed jets pump.

5.0 Power Requirements

Jacuzzi Premium spas are designed to provide optimum performance and flex-
ibility of use when connected to the maximum electrical service listed in the
tables below. If you prefer, your dealer can perform a minor circuit board
modification to allow your spa to accept an electrical service other than the
factory setting.

Page 8