beautypg.com

Edge pre-select mode, Cv-m4, Cl, cv-m7 – JAI M4+ CL User Manual

Page 17

background image

CV-M4

+

/M4

+

CL, CV-M7

+

/M7

+

CL

- 16 -

6.5. Edge Pre-select Mode

The trigger leading edge will start the exposure H synchronous or H a-synchronous (HC=0, HC=1).
The exposure stops and is read out after the shutter time selected. It can be the 10 steps in
normal or 1056 steps in programmable. SM=0 or SM=1. This mode will operate with full and
partial scanning and with V-binning (M4

+

and M4CL

+

only). Partial scanning and binning in

combinations is not allowed.
In this mode the Restart Continuous Trigger mode (RC=1) can be activated. (By RS-232C and CL
only). The camera is then running continuously, and it can be reset and restarted by the trigger
pulse.
If smearless read out (SL=1) is used, the exposure starts with a delay 133H (5.23 msec.) after the
trigger. An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that
the resulting video is read out.

To use this mode:
Set function:

Trigger mode “Edge Pre-select”

TR = 1

Shutter mode “Normal” or “Programmable”

SM=0, SM=1

“Shutter Speed”

SH=0 through 9

“Programmable exposure”

PE=0 through 1057

“H synchronous trigger”

HC=0, HC=1

“Restart Continuous Trigger”

RC=0, RC=1

“Smearless

readout”

SL=0,

SL=1

Polarity and other functions

Input:

Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.

Important notes on using this mode.

• The duration of the trigger should be >2H to <3V. (>72.64µsec to <120msec).
• The minimum trigger interval should be >(exposure time + 1 frame). A new trigger must

not be applied during the previous frame read out. (Before FEN is high).

• Smearless readout cannot be used together with Reset Continuous Trigger.

Fig. 20. Edge Pre-select