beautypg.com

Frame-delay read out mode, Cv-m4, Cl, cv-m7 – JAI M4+ CL User Manual

Page 20

background image

CV-M4

+

/M4

+

CL, CV-M7

+

/M7

+

CL

- 19 -

6.7. Frame-delay read out Mode

In this mode the pre selected exposure starts from the leading edge of the trigger pulse, H
synchronous or H a-synchronous. It can be the 10 steps in normal or 1056 steps in programmable.
SM=0 or SM=1. The resulting video is read out at the trailing edge of the trigger.
This mode will operate with full and partial scanning and with V binning (M4

+

and M4

+

CL only).

Partial scanning and binning in combinations is not allowed.
If smearless read out (SL=1) is used, the exposure starts with a delay 133H (5.23 msec.) after the
trigger. An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that
the resulting video is read out.

To use this mode:
Set function:

Trigger mode “Frame delay read out”

TR = 3

“H synchronous accumulation”

HC=0, HC=1

“Smearless

readout”

SL=0,

SL=1

Polarity and other functions

Input:

Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.

Important notes on using this mode.

• The duration of the trigger should be longer than the exposure time + (>2H to <3V.)

(>72.64µsec to <120msec).

• The minimum trigger interval should be >(trigger pulse width + 1 frame). A new trigger

must not be applied during the previous frame read out. (Before FEN is high).


Fig. 23 Frame Delay