Cv-m4+ command list, Cv-m4, Cl, cv-m7 – JAI M4+ CL User Manual
Page 25: Command list
![background image](/manuals/130120/25/background.png)
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
- 24 -
7.5. CV-M4
+
command list
Command Name
Format
Parameter
Remarks
A – General settings and useful commands
EB Echo Back
EB=[Param.]
1=Echo on
Off at power up
ST Camera Status request ST?
Actual setting
HP Online Help request HP?
Command list
VN Firmware version
VN?
3 letter version
B – Timing and shutter related commands
SC Scanning format
SC=[Param.]
2=1/4 partial
1=1/2 partial
3=1/8 partial
*1)
TR Trigger mode
TR=[Param.]
2=Pulse width
1=Edge
3=Frame delay
HC H synchronous accum
HC=[Param.]
1= H a-synchr
SM Shutter mode
SM=[Param.]
SH Shutter speed
SH=[Param.]
2=1/100
4=1/400
6=1/1500
8=1/5500
1=1/50
3=1/200
5=1/800
7=1/3000
9=1/10,000
All10 steps are
valid in normal
trigger mode.
PE Programmable expos.
PE=[Param.]
0=2.5 H,
1=3.5H
1055=1057.5 H
H= 39.3 µsec
Bin. H= 43.3 µsec.
BI
Binning
BI=[Param.]
0=off 1=vertical
*1). Only for SC=0.
M4
+
and M4
+
CL
SL
Smearless
SL=[Param.]
0=Off 1=ON
TR=1, 2 or 3
RC Reset Continuous Trig
RC=[Param.]
Only for TR=1
C – Signals and polarity
SO Sync on video
SO=[Param.]
Pin #4 on 12 pin
ML MuLtiple shutter
ML=[Param.]
Multi Trig input
TR=3
SE
Sync/EEN
SE=[Param.]
0= Sync out
1=EEN out
Pin #9 on 12 pin
FP FEN/LEN/EEN polarity
FP=[Param.]
1= active high
TP Trigger polarity
TP=[Param.]
1= active high
*2)
TI
Trigger Input
TI=[Param.]
0= Hirose 12p
1= LVDS (CL)
D – Gain and analogue signals setting
GA Manual gain Level
GA=[Param.]
Range 0 to 510
RP Rear Potentiometer
RP=[Param.]
1=rear potm.
SU Setup Level
SU=[Param.]
Range 0 to 255
E – Saving and loading data in EEPROM
LD Load settings from
camera EEPROM
LD=[Param.]
2=User 2 area
1=User 1 area
3=User 3 area
Latest used data
area becomes
default at next
power up
SA Save settings to
camera EEPROM
SA=[Param.]
3=User 3 area
2=User 2 area
Parameter = 0 is
not allowed
EA EEPROM area request
EA?
0=Factory data
3=User 3 area
1=User 1 area
3=User 3 area
Return the used
data from area
*3)
*1)
Binning can also be selected by the internal switch SW301.6. Binning has priority over partial scanning. If partial scanning
is active when a binning mode is activated, binning will take over and the scanning will be full. The line frequency will be
lower in V binning modes (H= 43.3 µsec.).
*2)
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
*3)
Data from the latest used data area is loaded as default on power up.
!!
Do not try to use commands not shown in the list.