beautypg.com

Cv-m4+ command list, Cv-m4, Cl, cv-m7 – JAI M4+ CL User Manual

Page 25: Command list

background image

CV-M4

+

/M4

+

CL, CV-M7

+

/M7

+

CL

- 24 -

7.5. CV-M4

+

command list

Command Name

Format

Parameter

Remarks

A – General settings and useful commands

EB Echo Back

EB=[Param.] 0=Echo off

1=Echo on

Off at power up

ST Camera Status request ST?

Actual setting

HP Online Help request HP?

Command list

VN Firmware version

VN?

3 letter version

B – Timing and shutter related commands
SC
Scanning format

SC=[Param.] 0=full frame

2=1/4 partial

1=1/2 partial

3=1/8 partial

*1)

TR Trigger mode

TR=[Param.] 0=normal

2=Pulse width

1=Edge
3=Frame delay

HC H synchronous accum

HC=[Param.] 0=H synchr

1= H a-synchr

SM Shutter mode

SM=[Param.] 0=Normal 1=Programmab.

SH Shutter speed

SH=[Param.] 0=Off (1/24)

2=1/100

4=1/400
6=1/1500

8=1/5500

1=1/50
3=1/200

5=1/800
7=1/3000

9=1/10,000

All10 steps are
valid in normal
trigger mode.

PE Programmable expos.

PE=[Param.]

0=2.5 H,

1=3.5H

1055=1057.5 H

H= 39.3 µsec
Bin. H= 43.3 µsec.

BI

Binning

BI=[Param.]

0=off 1=vertical

*1). Only for SC=0.
M4

+

and M4

+

CL

SL

Smearless

SL=[Param.]

0=Off 1=ON

TR=1, 2 or 3

RC Reset Continuous Trig

RC=[Param.] 0=Off 1=ON

Only for TR=1

C – Signals and polarity
SO
Sync on video

SO=[Param.] 0=no sync on v. 1=sync on v.

Pin #4 on 12 pin

ML MuLtiple shutter

ML=[Param.] 0=OFF 1=On

Multi Trig input
TR=3

SE

Sync/EEN

SE=[Param.]

0= Sync out

1=EEN out

Pin #9 on 12 pin

FP FEN/LEN/EEN polarity

FP=[Param.] 0= active low

1= active high

TP Trigger polarity

TP=[Param.] 0= active low

1= active high

*2)

TI

Trigger Input

TI=[Param.]

0= Hirose 12p

1= LVDS (CL)

D – Gain and analogue signals setting
GA
Manual gain Level

GA=[Param.] 0=low 510=high

Range 0 to 510

RP Rear Potentiometer

RP=[Param.] 0=manual gain

1=rear potm.

SU Setup Level

SU=[Param.] 0=low 255=high

Range 0 to 255

E – Saving and loading data in EEPROM
LD
Load settings from

camera EEPROM

LD=[Param.] 0=Factory data

2=User 2 area

1=User 1 area
3=User 3 area

Latest used data
area becomes
default at next

power up

SA Save settings to

camera EEPROM

SA=[Param.] 1=User 1 area

3=User 3 area

2=User 2 area

Parameter = 0 is

not allowed

EA EEPROM area request

EA?

0=Factory data
3=User 3 area

1=User 1 area
3=User 3 area

Return the used
data from area
*3)


*1)

Binning can also be selected by the internal switch SW301.6. Binning has priority over partial scanning. If partial scanning
is active when a binning mode is activated, binning will take over and the scanning will be full. The line frequency will be
lower in V binning modes (H= 43.3 µsec.).

*2)

If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.

*3)

Data from the latest used data area is loaded as default on power up.

!!

Do not try to use commands not shown in the list.

This manual is related to the following products: