beautypg.com

Regarding the indicator lamps, Incicator ( 50 – IBM CP-X445 User Manual

Page 50

background image

50

Troubleshooting

Regarding the indicator lamps

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP

indicator have the meanings as described in the table below. Please respond

in accordance with the instructions within the table. If the same indication is

displayed after the treatment, or if an indication other than the following is

displayed, please contact your dealer or service company.

POWER

indicator

LAMP

indicator

TEMP

indicator

Description

Lighting

In

Orange

Turned

off

Turned

off

The projector is in a standby state.

Please refer to the section “Power On/Off”.

Blinking

In

Green

Turned

off

Turned

off

The projector is warming up.

Please wait.

Lighting

In

Green

Turned

off

Turned

off

The projector is in an on state.

Ordinary operations may be performed.

Blinking

In

Orange

Turned

off

Turned

off

The projector is cooling down.

Please wait.

Blinking

In

Red

(discre-

tionary)

(discre-

tionary)

The projector is cooling down. A certain error

has been detected.

Please wait until the POWER indicator finishes blink,

and then perform the proper response measure using

the item descriptions below as reference.

Blinking

In

Red

or

Lighting

In

Red

Lighting

In

Red

Turned

off

The lamp does not light, and there is a

possibility that interior portion has become

heated.

Please turn the power off, and allow the unit to cool

down at least 20 minutes. After the projector has

sufficiently cooled down, please make confirmation of

the following items, and then turn the power on again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Does the peripheral temperature exceed 35°C?

If the same indication is displayed after the treatment,

please change the lamp by referring to the section

“Lamp”.

Blinking

In

Red

or

Lighting

In

Red

Blinking

In

Red

Turned

off

The lamp cover has not been properly fixed

(attached).

Please turn the power off, and allow the unit to cool

down at least 45 minutes. After the projector has

sufficiently cooled down, please make confirmation

of the attachment state of the lamp cover. After

performing any needed maintenance, turn the power

on again. If the same indication is displayed after

the treatment, please contact your dealer or service

company.