Configuration verification service aid – IBM H SERIES RS/6000 User Manual
Page 201
b. If you have just made changes to or have just turned on the system unit, you
might need to wait up to 30 seconds before detailed information about the
SSA network becomes available to the service aids.
4. When you have solved a problem, press F3 (Esc and 3 on some consoles) to
leave the display; then press Enter to reselect it. The display shows the new
status of the SSA links.
Configuration Verification Service Aid
The Configuration Verification service aid enables you to determine the relationship
between SSA logical units (hdisks) and SSA physical disk drives (pdisks). It also
displays the connection information and operational status of the disk drives.
Note: User applications communicate with the hdisks; error data is logged against
the pdisks.
To use the Configuration Verification service aid:
1. Select Configuration Verification from the SSA Service Aids menu to display a list
of pdisks and hdisks (see “Starting the SSA Service Aids” on page 7-31).
┌──────────────────────────────────────────────────────────────────────────────────┐
│ SSA SERVICE AIDS
8 238 │
┌──────────────────────────────────────────────────────────────────────────────────┐
│ CONFIGURATION VERIFICATION
8 239 │
│
│
│ Move cursor onto selection, then press Enter.
│
│
│
│
{TOP}
│
│
pdisk
22222222
- 3-P
9.1 GB SSA F Physical Disk Drive
│
│
pdisk1
33333333
- 5-P
9.1 GB SSA F Physical Disk Drive
│
│
pdisk2
44444444
- 7-P
9.1 GB SSA F Physical Disk Drive
│
│
hdisk3
22222222
- 3-L
SSA Logical Disk Drive
│
│
hdisk4
33333333
- 5-L
SSA Logical Disk Drive
│
│
hdisk5
44444444
- 7-L
SSA Logical Disk Drive
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
│
{BOTTOM}
│
│
│
│ F3=Cancel
F1 =Exit
│
│
│
└──────────────────────────────────────────────────────────────────────────────────┘
Chapter 7. Using the Service Aids
7-41