Industrial Redundant Ring Switch – Managed Switch Console Manual
Release No. : 0804-V1
2
1. Console Connection
RS-232 Connection
ICPDAS RS Series Switch is shipped with a 9-pin Female D-sub & RJ-45 cable
(CA-090510)
,
please use this cable to connect Switch’s RS232 port with PC’s COM port.
You can connect to Switch console by using windows Terminal Emulator,
Baud Rate
: 115200
Data Bits
: 8
Parity
: none
Stop Bit
: 1
Otherwise, you can download our free Console Emulator from RS Series Switch download
page:
http://www.icpdas.com/products/Switch/industrial/software.htm
Telnet Connection
Before using telnet to access console, please mask sure the PC host and Managed Switch are
on the same subnet.
Factory default:
IP Address
: 192.168.255.1
Gateway
: 192.168.0.1
Mask
: 255.255.0.0
Otherwise, you have to change the network setting through the RS-232 connection.
STEP 1
Click windows [Start]
[Run]
Type the Telnet command and switch’s IP address.
EX: telnet 192.168.255.1
STEP 2
If connection succeeds, the login prompt will appear.