background image

Industrial Redundant Ring Switch – Managed Switch Console Manual

Release No. : 0804-V1

12

Example

RTIME [time]

Description

Recovery time is the length of time it takes to return back to normal operation after an error

or other failure has occurred. This command enables you to set up the recovery time in

millisecond (ms).

Parameters

Parameter

Description

time

Provides the time interval(ms) that you want to set up as the

recovery time

Example

Return message: “recovery time X (Y) ms. ”

“X” ( switch value) indicates the rtime value set by console command,

“Y” (operating value) indicates the actual operating value.

Value can be specified only on Cyber-Ring Protocol Mode (refer to HMIVLAUE setting).

NOTE

Use the following function to calculate an adequate rtime:

rtime = [Round(0.3*(N+1))]*100 ms

N: number of switches

Example:

If there are 5 switches (including master switch), the adequate rtime will be: