ICP DAS USA RS-405/405F User Manual
Page 68
![background image](/manuals/128914/68/background.png)
Industrial Redundant Ring Switch
– RS Series User Manual
TDRS4050601
iii
Event Type 1: Power 1 Error
• Check for faulty power cord.
• Check for loose or broken power connections.
• Check connections to ensure the power and ground are attached to the correct terminals.
• Check for power loss or power surges at the AC power outlet.
• Check Voltage of power coming into Power 1 to ensure it is within +10 - +30V DC.
• Ensure there are no shorts between power and ground.
If the above fails, contact support.
Event Type 2: Power 2 Error
• Check for faulty power cord.
• Check for loose or broken power connections.
• Check connections to ensure the power and ground are attached to the correct terminals.
• Check for power loss or power surges at the AC power outlet.
• Check Voltage of power coming into Power 2 to ensure it is within +10 - +30V DC.
• Ensure there are no shorts between power and ground.
If the above fails, contact support.
Event Type 3: RS-232/RS-485 Connection Error
• Check for faulty cable line.
• Check for loose or broken connections.
If the above fails, contact support.
Event Type 4: Link Error
• Check if the corresponding DIP Switch (SW1) is “on”.
• Check for faulty or loose Cables(both ends). Visually inspect for loose or faulty connections at all
connectors and cables. If that does not correct the problem, try replacing the cable.