t
Time Status
Upper right section displays Time Status. You can monitor and configure current Time
setting interval in this section: Recovery Time(in the range 100-65535ms), Max Age
Time(in the range 6000-40000ms), Forward Delay(in the range 4000-30000ms), and
Hello Time (in the range 1000-10000ms). To make a modification, please type new
values in the fields that you would like to make a change of, and then click on the
button. Please note: the
button will appear
( gray out) before you input new
values. To make the value you input effectively, please click on
“Restart” button.
Note that the Switch Value indicates the value you configure and save on this Ring
Switch. However, only the Switch Value being set on Master Switch will be adapt as the
actual value (Operating Value) being applied to all switches in the same ring.
DIP Switch Status
This section shows current DIP Switch Status. Each jumper has two possible conditions:
on or off. Each position indicates one configuration state. To make a change of the
jumper state, please switch the jumpers on the Ring Switch directly and then click
“Restart” button to make the newly changed settings effective.