ICP DAS USA RS-405/405F User Manual
Page 62
Industrial Redundant Ring Switch
– RS Series User Manual
TDRS4050601
ccc
Rotary Switch (SW2) configuration
You can monitor current Switch 2 settings by this realistic image displayed. Check the
square box in front of
“HELP” to get more information.
W2 is a 16 position rotary switch on the front panel, right below the SW1. When the arm
of SW2 is switched to position "0", you would be able to set up specific values(Please go
to configuration page.) for recovery time(rtime), forward delay(ftime) , maximum
age(mtime), and hello time(htime) manually.
If it's on positions other than "0" ("1" to "F"), a set of preset values will be applied:
Roteray
SW position
F
E
D
C
B
A
9
8
Recovery
Time
1.5s
1.4s
1.3s
1.2s
1.1s
1.0s
900
ms
800
ms
Forwarding
Delay
30s
28s
26s
24s
22s
20s
18s
16s
Hello Time
10s
10s
10s
10s
10s
10s
10s
10s
Max Age
40s
40s
40s
40s
40s
38s
34s
30s
Roteray
SW position
7
6
5
4
3
2
1
0
Recovery
Time
700
ms
600
ms
500
ms
400
ms
300
ms
200
ms
100
ms
N/A
Forwarding
Delay
14s
12s
10s
8s
6s
4s
4s
N/A
Hello Time
10s
10s
8s
6s
4s
2s
1s
N/A
Max Age
26s
22s
18s
14s
10s
6s
6s
N/A