beautypg.com

ICP DAS USA RS-405/405F User Manual

Page 62

background image

Industrial Redundant Ring Switch

– RS Series User Manual

TDRS4050601

ccc

Rotary Switch (SW2) configuration

You can monitor current Switch 2 settings by this realistic image displayed. Check the
square box in front of

“HELP” to get more information.

W2 is a 16 position rotary switch on the front panel, right below the SW1. When the arm
of SW2 is switched to position "0", you would be able to set up specific values(Please go

to configuration page.) for recovery time(rtime), forward delay(ftime) , maximum

age(mtime), and hello time(htime) manually.

If it's on positions other than "0" ("1" to "F"), a set of preset values will be applied:

Roteray

SW position

F

E

D

C

B

A

9

8

Recovery
Time

1.5s

1.4s

1.3s

1.2s

1.1s

1.0s

900
ms

800
ms

Forwarding
Delay

30s

28s

26s

24s

22s

20s

18s

16s

Hello Time

10s

10s

10s

10s

10s

10s

10s

10s

Max Age

40s

40s

40s

40s

40s

38s

34s

30s

Roteray

SW position

7

6

5

4

3

2

1

0

Recovery
Time

700
ms

600
ms

500
ms

400
ms

300
ms

200
ms

100
ms

N/A

Forwarding
Delay

14s

12s

10s

8s

6s

4s

4s

N/A

Hello Time

10s

10s

8s

6s

4s

2s

1s

N/A

Max Age

26s

22s

18s

14s

10s

6s

6s

N/A

This manual is related to the following products: