Parameter

Specification

Unit

QA Test

Limits

Conditions

Notes

THD at Max. Output Power

less than 10 %

Maximum Output Power

Maximum THD as a result of limiting.

Output Volume Control
Volume Control Pot

YES

--

mounted on amp panel

Detent (center/#)

NO

--

Taper (lin/log)

log A taoer

--

@ minimum setting

no output

Input/Output Phase

Line Input vs. Hi Input

N/A °

Lo/Hi Input vs. Lo/Hi Output

N/A °

Input/Output
Line In (L,C,R,AC3,Mono)

Stereo

--

RCA phono jack, gold plated

LFE In

YES

--

Shared with "R" Line In jack

Signal Sensing (ATO)
Auto-Turn-On (yes/no)

YES

--

ATO Input Test Frequency

100 Hz

ATO Input Threshold

2 mV

typ.

LPF "On", BOS "Off"

ATO Low Pass cutoff

400 Hz

450

ATO-LPF for noise immunity

LPF "On", BOS "Off"

ATO Turn-on time

1 ms

10

Amp connected and AC on,

then input signal applied ( 1 W

output )

Auto Mute / Turn-OFF Time

10 minutes

5 < t < 15 Time before muting, after signal

is removed

Power on Features
Power on Delay time

greater than 2sec.

AC Power Applied

Power on LED

YES

--

Bi-color LED located on front of

cabinet

Normal On/Off

green / red color

ATO mode only

ATO

--

color

"Active": green; "Standby": red

Transients/Pops
ATO Transient

5 mV-peak

@ Speaker Output

Turn-on Transient

30 mV-peak

@ Speaker Output

AC Line cycled from OFF to ON

Turn-off Transient

30 mV-peak

@ Speaker Output

AC Line cycled from ON to OFF

Efficiency
Stand-by Input Power

10 Watts

typ.

@ nom. line voltage

AC Power Cons.@1W

12 Watts

typ.

@ nom. line voltage

Power Cons.@rated power

473 Watts

typ.

@ nom. line voltage

Input power measured is REAL Watts, not VA

Efficiency

63 %

typ.

@ nom. line voltage

Protection
Short Circuit Protection

YES

--

Direct short at output

Thermal Protection

YES

--

threshold ~ 65 deg. C at panel

DC Offset Protection

YES

--

DC present at Speaker Out

leads

Relay for driver/fire protection

Line Fuse Rating ( 120 V )

3.15 Amps

Type ADL or MDL

Fuse holder on inside surface of amp panel

AC Power & Transformer

Power cord length

9 feet

Double insulated cord,

AWG#18

TSS-SUB4000