beautypg.com

Troubleshooting – Icom IGM1600 User Manual

Page 29

background image

24

11

TROUBLESHOOTING

10

11

The transceiver does
not turn ON.

No sound from the
speaker.

Transmitting is impos-
sible, or high power
can not be selected.

The displayed channel
cannot be changed.

No beeps.

Self check error.
(Temperature)

Self check error.
(Battery voltage)

Transmitting continu-
ously while not speak-
ing when using VOX
function.

• The battery is exhausted.

• Bad connection to the battery pack.

• Squelch level is too deep.
• Volume level is too low.
• Speaker has been exposed to water.
• Water has entered the [MIC/SP] connector.

• Some channels are for low power or re-

ceive only.

• The battery is exhausted.

• The output power is set to low.

• Lock function is activated.

• Beep tones are turned OFF.

• The temperature is outside of –35°C to

+80°C; –31°F to +173°F (approx.).

• The connected battery pack’s voltage is

more than 11 V.

• Ambient noise is too loud.

• Change to a new battery pack (Survival).
• Recharge the battery pack (On-board).

• Check the connection to the transceiver.

• Set squelch to the threshold point.
• Rotate [VOL] to set a suitable level.
• Drain water from the speaker.
• Dry [MIC/SP] connector.

• Change channels.

• Change to a new battery pack (Survival).
• Recharge the battery pack (On-board).

• Push [Hi/Lo•

] to select high power.

• Push [Hi/Lo•

] for 1 sec. to cancel the

function.

• Set the beep tones to ON (Fix Beep/User

Beep) on the SET mode.

• Leave the transceiver at room temperature

for a while. Turn the power ON to check if the
internal temperature has returned to normal.

• Verify the battery voltage is correct.

• Remove the headset cable.
• Reduce the VOX gain setting.

p. 16

pgs.

17–20

p. 3

p. 9
p. 8


pgs. 8,

23

p. 16

pgs.

17–20

p. 8

p. 10

p. 12

p. 14

PROBLEM

POSSIBLE CAUSE

SOLUTION

REF.